UPS runtime calculator for NAS

How long will your setup actually run — after shutdown time and battery age are taken off? Add your devices, pick a UPS, and see which models leave a safe margin.

Your setup

A NAS with a few services needs 2–4 minutes to shut down; add VMs and containers and it climbs. 10 minutes covers a shutdown with room to spare.

Why the naive calculation lies

Watt-hours divided by watts is the starting point, not the answer. A sealed lead-acid battery cannot be taken to zero, and the inverter loses energy converting 12 or 24 V DC into mains AC — together those take roughly a third off the nameplate figure. Then the discharge rate bites: lead-acid delivers measurably less total energy when drained fast. The calculator above applies both corrections, plus battery age, and then subtracts the shutdown time you actually need. What is left is the margin that matters.

The practical consequence

Home NAS loads are tiny next to any UPS you would buy. A four-bay NAS at 45 W sits at a few percent of a 1500 VA unit, which is exactly where batteries behave well and runtime is generous. Get the load figure right first — a plug-in wattmeter for a week beats any estimate — and size for a clean shutdown, not for riding out the outage.