UPS for Proxmox VE

Install NUT on the Proxmox host itself — never inside a VM — and let the host stop its guests in order.

NUT version: NUT from Debian. Everything below is specific to this OS — the driver, the settings page, and the failure that is unique to it.

How UPS support works here

Proxmox VE is the parent of everything running on it. When the host shuts down, it asks each VM and container to stop, waits, and forces off any that do not respond. That is exactly the behaviour you want on UPS power, so the simplest correct design is: NUT runs on the host, and on a power event it calls a normal host shutdown. Install the nut package on the host, identify the UPS with nut-scanner -U, and configure /etc/nut/ups.conf with the driver (usbhid-ups for most units, port auto). Set MODE=netserver in nut.conf if other machines share the UPS, or standalone if not. Then restart nut-server and nut-monitor and check with upsc ups@localhost.

What goes wrong

The ordering is where Proxmox setups actually fail. A common homelab has a NAS that owns the UPS and also serves VM disks to Proxmox over NFS or iSCSI. If the NAS shuts down first, running VMs lose their disks mid-write — so the hypervisor must finish first, and it needs an earlier trigger than the NAS. A plain NUT secondary only shuts down when the primary declares the UPS critical, which is too late here; upssched lets the Proxmox host start its own shutdown a fixed time after the UPS goes on battery, while the NAS waits longer. Also: install the QEMU guest agent in every VM, or Proxmox cannot ask guests to stop cleanly and will force them off instead.

Recommended pairings

Best-documented pairing: Proxmox host as NUT server with the CyberPower CP1500PFCLCD (usbhid-ups). As a client of a NAS-owned UPS, Proxmox needs only nut-client and a MONITOR line pointing at the server. Copy-paste configs: NUT config generator.

Use the checker for your exact NAS and UPS, the NUT config generator for copy-paste configs, and the runtime calculator to check the shutdown margin. If the UPS is not detected at all, start at the Fix Finder.

Reviewed by Dharmen Bhambu · Last reviewed 29 November 2026. No lab tests have been completed yet — every verdict on this site shows its source. See how we check and the test log.