UPS for UGREEN DXP4800 Plus
The DXP4800 Plus has a UPS made for it — the US3000 — but only on UGOS. On TrueNAS it is invisible.
Typical power draw: about 22–40 W with drives running. These are typical figures from manufacturer specifications and community reports — not measured by us. Check your exact combination in the checker before buying.
The DXP4800 Plus is the UGREEN NAS where the UPS question gets interesting, because the answer changes completely with the operating system. On UGOS Pro, the matching UPS is UGREEN's own US3000: a 120 W DC unit that sits in the power path, talks to UGOS over USB, and gives about 10 minutes in UGREEN's stated scenario. UGREEN's official third-party list also marks the APC BE600M1 and BK650M2-CH as supported. On TrueNAS SCALE 25.10.4, the US3000 is not detected at all — TrueNAS ships NUT 2.8.0, and the US3000 needs NUT 2.8.3 or newer. That single version number is the difference between a working setup and a silent failure, and it is the reason this page exists. Also note the boundary: the US3000 does not support the DXP6800 or DXP8800 at all; those models need the US7000 (300 W) or a standard AC UPS.
Which UPS fits the DXP4800 Plus?
| UPS | Size | Waveform | Verdict | Source |
|---|---|---|---|---|
| UGREEN US3000 | 120 W DC | DC output | Works (UGOS) | UGREEN official list |
| UGREEN US7000 | 300 W DC | DC output | Works (UGOS) | UGREEN official list |
| APC BE600M1 | 600 VA / 330 W | Simulated sine | Works (UGOS) | UGREEN official list |
| APC BK650M2-CH | 650 VA / 390 W | Simulated sine | Works (UGOS) | UGREEN official list |
| UGREEN US3000 | 120 W DC | DC output | Not detected (TrueNAS) | TrueNAS forum, Jul–Sep 2026 |
| CyberPower CP1500PFCLCD | 1500 VA / 1000 W | Pure sine wave | Works (TrueNAS) | NUT HCL v2.8.3 |
How to set it up
Connect the USB cable that came in the box directly to the NAS — never through a hub. Enable UPS support in the operating system, choose USB UPS, and set the shutdown to trigger on low battery rather than after a fixed time: that rides out two-second flickers instead of shutting down for them. Then test it for real: pull the UPS input plug from the wall and watch the NAS enter Safe Mode or shut down. If it does not, the setup is not finished, however green the lights look.
What not to buy
Do not buy on VA alone. A 1500 VA unit at a 0.6 power factor carries 900 W — and your NAS draws a fraction of that. What matters is the waveform (pure sine wave for Active PFC supplies), the USB data connection, and whether your exact OS version has a driver for the model. The sizing tool works out the numbers; the checker answers the driver question.
See also: runtime calculator · NUT server setup · UPS not detected? Fix Finder
Reviewed by Dharmen Bhambu · Last reviewed 29 November 2026. No lab tests have been completed yet — every verdict on this site shows its source. See how we check and the test log.