UPS for Synology DS925+

The DS925+ is Synology's newest 4-bay Plus model — and no dedicated UPS page ranked for it when we checked.

Typical power draw: about 28–45 W with drives running. These are typical figures from manufacturer specifications and community reports — not measured by us. Check your exact combination in the checker before buying.

The DS925+ is the newest 4-bay in Synology's 2025 Plus range, and it is the model with the weakest search results for UPS advice: when we checked, the top results were power-adapter listings, not UPS guidance. That makes it the easiest entry point on this site — and the one where a wrong guess costs the most, because the buyer is usually setting up a new NAS and a new UPS in the same order. The good news is that the DS925+ speaks the same USB HID protocol as the DS923+ before it, so the well-reported pairings carry over. The bad news is that 'carries over' is not a test: Synology's published 79-entry tested list is a category list, not a per-model one, so nothing here claims the DS925+ itself was tested with a given UPS.

Which UPS fits the DS925+?

UPSSizeWaveformVerdictSource
APC BE600M1600 VA / 330 WSimulated sineLikely worksNUT HCL v2.8.3
CyberPower CP1500PFCLCD1500 VA / 1000 WPure sine waveLikely worksNUT HCL v2.8.3
APC BR1500MS21500 VA / 900 WPure sine waveLikely worksNUT HCL v2.8.3
CyberPower CP850PFCLCD850 VA / 510 WPure sine waveLikely worksNUT HCL v2.8.3

How to set it up

Connect the USB cable that came in the box directly to the NAS — never through a hub. Enable UPS support in the operating system, choose USB UPS, and set the shutdown to trigger on low battery rather than after a fixed time: that rides out two-second flickers instead of shutting down for them. Then test it for real: pull the UPS input plug from the wall and watch the NAS enter Safe Mode or shut down. If it does not, the setup is not finished, however green the lights look.

What not to buy

Do not buy on VA alone. A 1500 VA unit at a 0.6 power factor carries 900 W — and your NAS draws a fraction of that. What matters is the waveform (pure sine wave for Active PFC supplies), the USB data connection, and whether your exact OS version has a driver for the model. The sizing tool works out the numbers; the checker answers the driver question.

See also: runtime calculator · NUT server setup · UPS not detected? Fix Finder

Reviewed by Dharmen Bhambu · Last reviewed 29 November 2026. No lab tests have been completed yet — every verdict on this site shows its source. See how we check and the test log.