NUT config generator

Pick your UPS and your setup. The generator writes ups.conf, upsd.conf, upsd.users and upsmon.conf for you — copy, paste, restart, verify with upsc.

Your setup

Generated configs are starting points from the driver table in the NUT server setup guide. They have not been tested on your hardware — verify with upsc and a real pull-the-plug test before trusting them.

After generating

  1. Paste each block into the matching file under /etc/nut/ (or the TrueNAS / Unraid settings panel).
  2. Restart the NUT services: systemctl restart nut-server nut-monitor.
  3. Verify with upsc ups@localhost — you should see battery charge, runtime and ups.status: OL.
  4. Pull the UPS input plug from the wall and confirm the shutdown happens. If it does not, the config is not finished.

Driver details and the full explanation are in the NUT server setup guide.

Reviewed by Dharmen Bhambu · Last reviewed 29 November 2026. No lab tests have been completed yet — every verdict on this site shows its source. See how we check and the test log.