NUT config generator
Pick your UPS and your setup. The generator writes ups.conf, upsd.conf, upsd.users and upsmon.conf for you — copy, paste, restart, verify with upsc.
Your setup
Generated configs are starting points from the driver table in the NUT server setup guide. They have not been tested on your hardware — verify with upsc and a real pull-the-plug test before trusting them.
After generating
- Paste each block into the matching file under
/etc/nut/(or the TrueNAS / Unraid settings panel). - Restart the NUT services:
systemctl restart nut-server nut-monitor. - Verify with
upsc ups@localhost— you should see battery charge, runtime andups.status: OL. - Pull the UPS input plug from the wall and confirm the shutdown happens. If it does not, the config is not finished.
Driver details and the full explanation are in the NUT server setup guide.